Hydraforce.pl · Salus Hydraulics technical websiteInternational engineering enquiries →
Discuss your requirements
HydraForce / technical selection

How do you select a coil and controller for a HydraForce valve?

Similar appearance and matching voltage are not enough. The assembly must be mechanically, electrically and functionally compatible with the valve and machine.

Start with the valve, then the coil

Identify the full valve designation and existing coil number. Record mounting dimensions and connector type. Include a photograph of the valve section on which the coil is fitted.

Do not assume that a valve shown in a product photograph is supplied with a coil. The scope of supply depends on the specific version and offer.

Power supply involves more than rated voltage

Check the supply type, ratings and control method specified for the coil. Proportional systems also depend on the current characteristics and controller output capability.

Set PWM frequency, dither and current limits according to the documentation for the particular assembly. One setting is not suitable for all HydraForce valves.

What must the controller support?

AreaQuestions to resolve
OutputsHow many coils need controlling? What current and load type does each channel support?
InputsWhat signal comes from the joystick, sensor or supervisory controller?
CommunicationIs CAN / J1939 or another interface required? Check the specific device version.
DiagnosticsHow will an open circuit, signal loss and power supply faults be detected?
Machine behaviourWhat should happen after loss of power and when power is restored?

Replacing an old part number with a new one

An older number may lead to information about a newer version. This is a starting point for verification, not proof of interchangeability. Compare mounting, connector, ratings and change documentation before ordering.

Configuration does not replace system commissioning

The programme or configuration file must suit the device and application. Library examples are not ready-to-use programmes for any machine. Agree the functional verification and test scope for the particular system.

Technical source: HF-Impulse and supported devices. Use the datasheet for the specific version during selection.